Skip navigation
DSpace logo
  • Home
  • Browse
    • Communities
      & Collections
    • Browse Items by:
    • Issue Date
    • Author
    • Title
    • Subject
  • Sign on to:
    • My DSpace
    • Receive email
      updates
    • Edit Profile

  1. DSpace at My University
  2. Department of Soil and Water Conservation Engineering
  3. Project Report-SWCE
Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/2407
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAMAYA P-
dc.contributor.authorRAHANA SATHAR-
dc.contributor.authorAVANTHIKA K-
dc.contributor.authorSHEEJA P S, (Guide)-
dc.date.accessioned2026-07-20T08:47:26Z-
dc.date.available2026-07-20T08:47:26Z-
dc.date.issued2026-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/2407-
dc.description.abstractThis project focuses on solving the problem of water wastage caused by undetected leaks in agricultural irrigation pipelines. Standard inspection methods are slow and often locate leaks only after significant amounts of water have been lost. To fix this delay, this study designs and tests a low-cost, automated Internet of Things (IoT) system that monitors pipelines continuously and catches leaks in real time. The system layout features a 4-meter PVC pipeline, a water pump, and two inexpensive YFS201 flow sensors installed at the pipeline's inlet and outlet. An ESP32 microcontroller constantly reads the water flow data from both sensors. When a leak occurs, it creates an imbalance between the inlet and outlet flow rates; if this difference crosses a pre-set limit, the ESP32 automatically rings a buzzer, turns on a warning LED, sends an text message to the operator using a GSM module, and trips a relay to shut off the pump immediately. The experimental prototype was tested under two different leak conditions using a bypass valve to simulate a pipe break. The system successfully achieved a 100% detection rate and caught every simulated leak in an average time of just 5.073 seconds. By shutting down the system so quickly, the automated setup tightly limited water loss to minor amounts (about 1 L per event), proving it is a highly dependable and practical solution for smart water conservation in farmingen_US
dc.language.isoenen_US
dc.publisherSWCE, KCAET, Tavanuren_US
dc.relation.ispartofseriesP;681-
dc.titleWATER LEAKAGE DETECTION IN IRRIGATION PIPELINE USING IoTen_US
dc.typeThesisen_US
Appears in Collections:Project Report-SWCE

Files in This Item:
File Description SizeFormat 
P_681.pdf
  Restricted Access
1.57 MBAdobe PDFView/Open Request a copy
Show simple item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Theme by Logo CINECA

DSpace Software Copyright © 2002-2022  LYRASIS - Feedback